- SECTION 06062
-
- MEDIUM DENSITY FIBERBOARD
- NOTE ** This section is based on products manufactured by
- Medite Division of Sierra Pine Ltd., at the
- following address:
- NOTE ** P.O Box 4040
- NOTE ** Medford OR 97501
- NOTE ** Voice (800) 676-3339 and (503) 773-2522
- NOTE ** FAX (503) 779-9921
- NOTE **
- NOTE ** Medite offers standard, specialty, fire-rated, and
- non-rated Medium Density Fiberboard products for
- cabinet work, countertop, and panel work. Medium
- Density Fiberboard is noted for its workability,
- and for its smoothness to receive laminates,
- veneers, and gloss opaque finishes.
- NOTE **
- NOTE ** SECTION 06062 - MEDIUM DENSITY FIBERBOARD,
- Copyright 1996, The Architect's Catalog, Inc.
-
-
- PART 1 GENERAL
-
- 1.1 SECTION INCLUDES
- NOTE ** Delete items below not required for project.
-
- A. Medium density fiberboard for fabricated wood items.
-
- 1.2 RELATED SECTIONS
- NOTE ** Delete any sections below not relevant to this
- project; add others as required.
-
- A. Section 06200 - Finish Carpentry.
-
- B. Section 06400 - Architectural Woodwork.
-
- 1.3 REFERENCES
- NOTE ** Delete references from the list below that are not
- actually required by the text of the edited
- section.
-
- A. ANSI A208.2 - Medium Density Fiberboard for Interior Use.
-
- B. UL 723 - Standard for Test for Surface Burning
- Characteristics of Building Materials.
-
- 1.4 SUBMITTALS
-
- A. Submit under provisions of Section 01300.
-
- B. Product Data: Manufacturer's descriptive literature for
- specified products; indicate conformance to specified
- requirements.
-
- C. Manufacturer's Instructions: Recommendations for
- fabrication and finishing techniques using specified
- products.
-
- 1.5 DELIVERY, STORAGE, AND HANDLING
-
- A. Storage and Protection: Store products of this section
- on flat, level surface, supported to prevent sagging;
- maintain dry, heated storage area until products are
- used.
-
- 1.6 SEQUENCING
-
- A. Supply products of this section to fabricators requiring
- them in time for conditioning products to environment
- minimum two days before fabrication.
-
- PART 2 PRODUCTS
-
- 2.1 MANUFACTURERS
-
- A. Acceptable Manufacturer: Medite Division of Sierra Pine
- Ltd.; P.O Box 4040, Medford OR 97501. ASD. Voice (800)
- 676-3339 and (503) 773-2522, FAX (503) 779-9921.
- NOTE ** Delete one of the two following paragraphs;
- coordinate with Division 1 requirements.
-
- B. Requests for substitutions will be considered in
- accordance with provisions of Section 01600.
-
- C. Substitutions: Not permitted.
-
- 2.2 MATERIALS
- NOTE ** Delete products not required for project in the
- following three paragraphs.
-
- A. Medium Density Fiberboard, Exterior Grade:
- 1. Acceptable Product: Medex.
- 2. Physical Characteristics: Wood-based panel product,
- manufactured from softwood fibers, minimum 90% of
- which obtained from wood residuals, bonded under heat
- and pressure with formaldehyde-free synthetic resin
- binders, meeting requirements of ANSI A208.2 Product
- Class MD-EXTERIOR, and having the following
- properties for sheet material thicknesses up to, and
- including, 3/4 inch:
- a. Density: Minimum 46 pounds per cubic foot.
- b. Internal Bond Strength: Minimum 130 pounds per
- square inch.
- c. Modulus of Rupture: Minimum 5,600 pounds per
- square inch.
- d. Modulus of Elasticity: Minimum 575,000 pounds
- per square inch.
- e. Hardness: Minimum 1000 pounds, Janka modified.
- f. Screw-Holding Capacity: Pounds of force required
- to pull 1 inch long No. 10 sheet metal screw from
- material:
- 1) Face: Minimum 325 pounds.
- 2) Edge: Minimum 275 pounds.
- g. Moisture Content: Maximum 6 percent.
- h. Panel Thickness Tolerance: 0.005 inch, plus or
- minus.
-
- B. Medium Density Fiberboard, Interior Grade:
- 1. Acceptable Product: Medite II.
- 2. Physical Characteristics: Wood-based panel product,
- manufactured from softwood fibers, minimum 90% of
- which obtained from wood residuals, bonded under heat
- and pressure with formaldehyde-free synthetic resin
- binders, meeting requirements of ANSI A208.2 Product
- Class MD, and having the following properties for
- sheet material thicknesses up to, and including, 3/4
- inch:
- a. Density: Minimum 46 pounds per cubic foot.
- b. Internal Bond Strength: Minimum 115 pounds per
- square inch.
- c. Modulus of Rupture: Minimum 5,200 pounds per
- square inch.
- d. Modulus of Elasticity: Minimum 520,000 pounds
- per square inch.
- e. Hardness: Minimum 1150 pounds, Janka modified.
- f. Screw-Holding Capacity: Pounds of force required
- to pull 1 inch long No. 10 sheet metal screw from
- material:
- 1) Face: Minimum 325 pounds.
- 2) Edge: Minimum 275 pounds.
- g. Moisture Content: Maximum 6 percent.
- h. Panel Thickness Tolerance: 0.005 inch, plus or
- minus.
-
- C. Medium Density Fiberboard, Fire Retardant:
- 1. Acceptable Product: Medite FR.
- 2. Physical Characteristics: Wood-based panel product,
- manufactured from softwood fibers, minimum 90% of
- which obtained from wood residuals, saturated with
- fire-retardant additives, then bonded under heat and
- pressure with formaldehyde-free synthetic resin
- binders, meeting requirements of ANSI A208.2 Product
- Class MD, and having the following properties for
- sheet material thicknesses up to, and including, 3/4
- inch:
- a. Density: Minimum 45 pounds per cubic foot.
- b. Internal Bond Strength: Minimum 100 pounds per
- square inch.
- c. Modulus of Rupture: Minimum 3,500 pounds per
- square inch.
- d. Modulus of Elasticity: Minimum 375,000 pounds
- per square inch.
- e. Hardness: Minimum 1000 pounds, Janka modified.
- f. Screw-Holding Capacity: Pounds of force required
- to pull 1 inch long No. 10 sheet metal screw from
- material:
- 1) Face: Minimum 300 pounds.
- 2) Edge: Minimum 225 pounds.
- g. Moisture Content: Maximum 6 percent.
- h. Panel Thickness Tolerance: 0.005 inch, plus or
- minus.
- i. Fire Resistance: Class 1 surface flame spread
- when tested in accordance with UL 723.
-
- D. Fasteners: Supply fasteners, type recommended by panel
- manufacturer for conditions indicated, to fabricators
- requiring them.
-
- PART 3 EXECUTION - Not Used.
-
- END OF SECTION
-